Navis Engine Disassembly Caloris Exchanger
Disassembly Tab Caloris Exchange pro HVAC Industry
Disassembly Plate Heat Exchanger for the Automotive Industry and Paper Industry
Disassembly Tab Caloris Exchange in Cibus Industry
Disassembly Tab Caloris Exchange pro Chemical Fiber IndustryProductum Danielis structuram delapsum laminam caloris commutatoris
Components laminae calor exchanger
Forum et Application
Diu Jiangyin Daniel Cooler commissum est, ut summus qualitas laminae caloris nummulariorum clientium in petrolei, chemica, industriali, cibo et potu, potestate, metallurgia, aedificatione, HVAC et aliis industriae in multis regionibus et regionibus compararet, commissum est. Nunc, plus quam 20000 patellae nummulariorum caloris in variis industriis bene operantur.
Lamina commoda caloris nummulariorum
Fluxum liquoris inter laminas formare turbulentum promovere. Admitte laminam metallicam diversis pressionibus accommodare. Alveus fluens "herringbone" parvae laminae exemplaris componitur ex duabus laminis adiacentibus cum herringbone angulus differentia 180 graduum. Plures ergo sunt puncta anguli inter laminas, quae ad unum punctum quodvis 130mm attingere possunt. Alveus fluens non est pronus ad deformationem, habet reluctationem relative altam resistentiam, et potest sustinere gravem uim differentiam. Eodem tempore, cum fluxus sit tres dimensiva et turbulentia secundum quid intensa, calor coefficiens est altus trans- latio.
|
Foedus compages |
Spatium, quod a bractea commutatoris caloris occupatum est, inter omnia genera caloris nummulariorum minimus est. Sub eodem calore commutationis condiciones, tabulatum laminae caloris commutatoris solum 1/3 ad 1/4 illius testae et tubi commutatoris caloris est, nec addito spatio conservante disgregatus eget.
|
|
Princeps calor translatio coefficientis |
Ob hoc quod medium fluit in laminam coetus turbulentum formare potest ad numerum relativum Reynoldum (Re), et implicitum minus probabile est formare in laminas laeves, ipsum calorem transferendi efficientiam altissimum habet. In genere aquae-ad-aquarum calor commutationem, calor coefficiens laminae calor commutator transferre potest super 6000w/m , quod est 3 ad 8 tempora altior quam putamen et fistulae caloris commutatoris.
|
|
Princeps calor recuperatio rate |
Ob altitudinem caloris coefficiens translatio, optimae rationis fluxus proprietates et omnino contraria fluunt, calor translatio temperatus differentia nimis eligi potest. Ergo aptissima est vis caloris humili gradu recuperare. Nationibus oeconomice fieri potest ut ratam recuperationem calefactionis consequi supra 90% per unam laminam caloris commutatoris utatur.
|
|
Magna aptabilitas |
Patina plicabilis commutator singularis caloris adaptationem habet. Post institutionem, globus lamina metallica augeri vel minui potest obviam processui exigentiis expansionis vel contractionis.
|
|
Humilis stagnantis fluxus |
Ob parvum eius canalem fluens et fluentem minime stagnantem, cito incipere potest, prompte respondere cum operationes moderari mutare ac pondus armorum significanter minuere.
|
|
Commodum ad victum |
Consilium laminarum efficit ut nullae anguli mortui sint, ergo purgatio chemica in-site sine disassembly exerceri potest. Ad delapsum laminam caloris nummularii, facile etiam aperiri possunt ad purgationem penitus mechanicam.
|
Jiangyin Daniel Cooler Co., Ltd. (Daniel Cooler) anno 2004 condita est. Est fabrica caloris commutatoris, quae delapsum laminam caloris nummularii producit (PHE), gasketes gasketes commutatorus (PHEGASKET), calor cambiarii (PHEPLATE) et bracteae caloris commutationes sustentationis officia praebet (PHEMAINTENANCE).
Jiangyin Daniel Cooler consilium et productionem technicae artis et cognitionis caloris commutatoris habet. Jiangyin Daniel Cooler commissum est ut laminam qualitatem caloris nummulariis praeberet clientibus petrolei, chemica, industrialis, cibi et potus, electricitatis, metallurgiae, aedificationis, HVAC et aliarum industriarum in multis regionibus et regionibus.
Peculiaris lamina caloris commutatoris laminae et gasketulae globulus designari et fabricari potest secundum necessitates mos
Tabula caloris commutatoris iuvantis habena exempla: M3, M6B, M6M, M6MX-L, M6MX-R, M10B, M10M, M15B, M15Blip, MK15BW, M15M, M20M, MX25B, MX25M, M30, MA30M, MA30W, EC500, AM20, P31-HBM, MK; MX25, Ec350, TL6B, TL10B, TS20M, TS6M, AM30, P22, P26, P31, P32, P36, A15B, A15M, A10, A10B, T20B, T20M, TS20M, P36, TL10B, T20P, AX30, clip8, AX30, AX30B, JWP36, EC50, EC150, EC350, EC500.
Saccharum industria, industria metallurgicae caloris commutatoris gasket globulus signatus gasket EC50, EC150, EC350, EC500, EC500-WTEL, EC500-WTFE, EC500-ETFC, EC500-TFR, EC50-WTEL, EC50-WTFEEC50-ETFC, EC50-TFR, EC350-WTEL, EC350, EC350-WTEL, EC350, EC350-WTEL, EC350-WTEL
Plate heat exchanger gasket model: T4, H17, N35, N25, SR2, N50, A055, J060, M92 (adhesive), J092, A085, J107, Q080, K34, K55, K71 (adhesive), P105, M60, P190, U2, E201, SR3, Q030, Q055, J185, SR6, H12, SR1, RS3
Plate heat exchanger gasket models: VT4, VT8, VT10, VT20, VT20, N40, VT40, VT80, VT130, VT1306, VT2508, VT2508 B-10, VT2508 B-16, VT2508 B NT250S, NT50X, NT100T, NT100M, NT100X, NT150S, NT150L, VT405, NT250S, NT250L VICARB
Plate heat exchanger gasket models: V10, V20 (button type), V20 (F paste), V45 (button type, paste type), V60 (paste type), V85 (paste type), V130, V4, V13, V20, V28, V45, V60A, V60B, V85, V85D, V100A, 100B, V110A, V130A, 100B, V110A, V130, V4, V13, V20, V28, V45, V60A, V60B, V85, V85D, V100A, 100B, V110;
Plate caloris commutatoris exemplar iuvantis codex: GX-12, GX-12P1, GX-018, GX-26, GC-26, GX42, GC42, GC-30PI, GC-60PI, GX-LI, GC-LI, GX-LX, GX-C, GX-CLXXX;
Patinae caloris commutatoris exemplar iuvantis codex: Sigma9, Sigma26, Sigma27, Sigma37, Sigma66, Sigma76, Sigma114, Sigma7, Sigma X29, Sigma M37, Sigma38, Sigma M66, Sigma 107, Sigma90SAL
Plate calor exchanger rubber signationem gasket exemplar: S4, S7, S8, S9, S14, S15, S15FS, S21, S22, S30, S37, S39, S41, S43, S47, S50, S62, S65, S81, S83, S121
Tabula caloris cambiatoris anuli signandi exemplar: TL90PP, TL90SS, TL150PP, TL150SS, TL200PP, TL200SS, TL250PP, TL250SS, TL400SS, TL500PP, TL500SS, TL650PP, TL650SS, TL850PP, TL850SS
Tabula caloris gasket commutatoris exemplar: RX-LXX, LX50A, EX-XV, EX-16, UX416, UX-01, UX-05, UX-20, UX-30, UX-XL excogitari possunt et fabricari secundum exigentias mos.
Specialis laminae caloris commutatoris laminae et gastellae Flexilis praecipua exemplaria laminae caloris cambiarii et gasketes globulus;
1. Plate calor laminae exchanger. M3, M3 (N), M3X, M6-MFL, M6MD, M10 (MFML, MFGL, M10BD, M10BW), M10-BFGL, M15-(MFG, MFML, FFM, BFG), M15-MFGL, M15-BFML, M20-MFM, M20-MWFM, M20-FKMX, MMX XXV; AK20-FGL (E, F), A10 (B), A15, A15B, A15BW, A20, A20B, A3, A35, AX30, TS6, TS20, TL6, TL10, TL15, T20, C6, C8, C10. AC400. AC600, AV170, AV280 .
2. Plate heat exchange plates exchanger A055.AO85, CHF130, H12, H17, H17PA, H17DS, J060, J092, J107, J185, K34, K55, K71, K71PA, M60, M92, M185, M107, N35, N35DS, N35PA, N50, Q030D, Q0, Q055D, Q030D, K71PA, M60, M92, M185, M107, N35, N35DS, N35PA, N50, Q030D, Q0D, Q055D, Q030D, K71PA, M60, M92, M185, M107, N35, N35DS, N35PA, N50, Q030D, Q0. R14S, R23, R40S, R5, R55, R66, SR2, SR3, SR9, SR14, BR1.06, BR034, BR028, BBL1.6TAF, BBL1.6BF, BR1.08CF? N35, N25, N50, AO55, H17;
3. Plate laminae caloris commutatoris: GX-51, GX-013, BR013 (canaliculi genus), GX-108, GX-214, GX-26, GC-26, UFX-26= GX-26GX-26, GX-LI, GX-C, GX-LX, GX-180, GC-26, GC-XLV. Sondex: S14, S15, S15FS, S21, S30, S41, S43, S50, S65, S83... HISAKA, W.Schmidt .......
4. Plate caloris commutatoris laminarum NT150L/N40/FA157/FA158/AF161/FA184NG/FA184WG/FA192NG/FA192WG/VT10/VT20/VT2
5. BR series laminae caloris commutatoris laminis productae in serie g BR, BR005, BR01, BR03, BR05, BR08, BR13.




Applicatio laminae Danielis gasket cambiarii caloris;
Navis industria: maxime usus est ad refrigerandum, iaccam aqua refrigerandum, oleum refrigerandum, piston refrigerandum, refrigerandum, transmissio oleum refrigerandum, cibus gravis oleum preheating, diesel preheating, alii processus refrigerationem, etc.
Potentia industria: caloris nummularii praecipue adhibentur in cyclo aperto vel clauso aqua refrigerationis, transmissio olei refrigerationis, turbines olei refrigerationis, lubricationis oleum refrigerationis, pistonis et turbines et engine coolant refrigerationis, diesel potentia statio caloris recuperatio, consumptio gasi caloris recuperatio.
Calor nummulariorum praecipue adhibentur in industria pharmaceutica pro: medicamento sterilizationis, emulsio refrigerationis, suspensionis calefactionis, plasmatis calefactionis, acidi citrici calefactionis, infusionis refrigerationis, etc., ferri industria caloris nummularii praecipue adhibentur in industria ferri ad fingunt/continuum mittentes machina refrigerationis refrigerationis, oleum hydraulicum/ oleum refrigerationis refrigerationis, apparatus refrigerationis refrigerationis, infrigidationis electrofe. aqua/emulsio/coctio plantae aquae extenuationis refrigeratio, corpus fornax/electrica firmamentum/transformator refrigerans refrigerans.
Calor nummulariorum praecipue adhibentur in industria HVAC pro: regio calefactio, aqua calida domestica, glacies reposita, assidua calefactio piscinarum natantium, cogitationes æstus sentinæ, calor recuperandi cogitationes, aqua preheating calefactio, aqua geothermal / vapor utendo, etc.
Calor nummulariorum praecipue adhibentur in industria chemicae pro: calefactione et refrigeratione instrumentorum processus, oleum refrigerationis, refrigerationis electrolyticae, calefactionis liquoris degraescentis, phosphating liquoris refrigerantis, etc.